From the HMI screen, set up the 6. Communication settings
From the HMI screen, set up the 6. Communication settings
- Download Modicon Libraries 2022 - General Purpose V2 for Control Expert V15.1
- Install the Libraries following the installation guide provided and adjust the PLC settings accordingly
In the OTM (Web browser) edit the IP address:
- Connect to the Web Server of the TPRBCEIP bus coupler at 10.10.0.1
- Add the VFD to the device list in the DTM Browser
- In the properties of the network card (e.g. CPU network or NOC network) edit the IP and Disable the DHCP option for the VFD, so that it will work by Fixed IP addressing
- Launch the Schneider program "PLC Simulator" app
- From Control Expert PLC tab, set "Simulation Mode" and "Connect" to the PLC
- From Control Expert PLC tab, "Transfer Project to PLC"
- Click on "Run" button to set the PLC SIM in Run mode
- Safety Loop must have only safety equipment
Operating mode: S-Sensor > S-Input module > S-CPU & Co-processor > S-Output module > S-Actuator
- Add a dedicated safety module to the drive (VW3A3809), that is located behind the HMI and the green cover for the ATV900 (and on the top right for the ATV340 in the slot GP-SF)
- COLD: Full PLC download with PLC STOP: PLC > Connect > Transfer Project to PLC
- WARM: Online edit without PLC STOP: PLC > Connect. Build > Build changes
- “SoMove” for variable frequency drives configuration:
SoMove | Schneider Electric UK (se.com)
- Check on the “DTM Browser” that the security settings for the communication card are unlocked (FTP, TFPR, etc).
- Technical SupportOn the Schneider website: mySchneider (se.com)
- Modicon M580, Safety System Planning Guide: Modicon M580, Safety System Planning Guide | Schneider Electric (se.com)
- Download “General Purpose Library”: Modicon Libraries 2022 - General Purpose V2 for Control Expert | Schneider Electric